cylindrical battery ten-channel battery sorters are used for 18650 and 21700 cylindrical battery internal resistance, voltage and other parameters of the detection and sorting equipment, equipment is equipped with high precision internal resistance
CY-BS-LD10 cylindrical battery ten-channel battery sorters are used for 18650 and 21700 cylindrical battery internal resistance, voltage and other parameters of the detection and sorting equipment, equipment is equipped with high precision internal resistance, voltage automatic tester and control computer, according to the computer software set on the internal resistance, voltage value accurately send the battery into the designated gear. The system can achieve up to 10 levels (1 test station, 10 sorting levels) sorting. The equipment has high efficiency and can test about 5000 cells per hour.
1. The equipment is simple to operate, without professional training, and the workers can easily master it;
2. The voltage internal resistance can be sorted according to the set level, easy to operate and learn;
3. High precision of sorting instruments and equipment;
4. The test instrument can collect data;
5. Feed, transport and receive PLC control;
6. Panasonic PLC and Panasonic servo motor, brand sensors and other accessories, stable performance.
If you are interested in our cylindrical battery ten channel battery sorting machine, please contact us for more information and a quote.
Phone:+86 136 6380 8508
Email:jason@cysitech.com
Sales manger:Jason.Zhang
WhatsApp:+86 150 3827 2566
Wechat:cykytech
Power source | Single-phase AC220V±10%/50Hz |
Input power | ≤800W |
Working air source | 0.5 ~ 1.0 Mpa |
Applicable cell specifications | 18650, 21700 finished batteries |
Sorting efficiency | ≥80PPM |
Sorting parameter | Ac internal resistance, open circuit voltage |
Ac internal resistance | Accuracy ±0.1%rdg, display resolution 0.01mΩ |
Open-circuit voltage | Accuracy ±0.01%rdg, display resolution 0.1mV |
tester | Domestic precision voltage internal resistance tester |
computer | Industrial computer |
Equipment size | L1320mm*W860mm*H1200mm |
weight | Approx. 200Kg |
Experiment preparation
1. Material preparation: Prepare an appropriate amount of assembled cylindrical lithium batteries, including the batteries that have completed the assembly of positive and negative electrode sheets, electrolyte injection and packaging.
2. Tools: In addition to the cylindrical battery 10-channel battery separator, you also need to prepare gloves, scissors, rulers and other auxiliary tools.
3. Environment preparation: Ensure that the operation area is clean and dust-free, and that the temperature and humidity meet the technical requirements to avoid the impact of static electricity and dust. The operation area should be equipped with a ventilation system to prevent the accumulation of harmful gases.
Experimental procedure
Battery pretreatment:
Place the assembled cylindrical lithium battery on the operating table to check for leaks or other defects.
Confirm the packaging effect of the battery to ensure that the aluminum shell and the internal components of the battery fit well, no bubbles and leaky sealing phenomenon.
Parameter setting:
1. According to the battery specifications and sorting requirements, set the test parameters of the cylindrical battery 10-channel battery sorting machine, including voltage, internal resistance, capacity, etc.
2. Small batch test can be carried out first, adjusted to the best state and then officially put into production.
Battery loading:
1. Place the battery at the feed port of the cylindrical battery 10-channel battery sorter to ensure the correct and stable position of the battery.
2. Adjust the speed of the conveyor belt so that the battery enters the test channel successively.
Sorting operation:
1. Start the sorting procedure, and the sorting machine will automatically test each battery with multiple parameters, including voltage, internal resistance and capacity.
2. After the completion of the test, the separator distributes the battery to different exit channels according to the preset separation standards to ensure that the battery performance of each channel is consistent.
3. Record the number of batteries and performance data of each channel to ensure the accuracy of the sorting results.
Quality inspection:
1. Carefully check the battery after each channel sorting to ensure that there is no missed detection or misjudgment.
2. Use a multimeter, charge and discharge tester, and other tools to perform detailed testing and record relevant data.
Performance test:
1. Randomly select some samples for charge-discharge cycle test to evaluate key indicators such as capacity retention rate and internal resistance of the battery.
Record the test results and analyze the effect of sorting on battery performance.
Result analysis
Through the use of cylindrical battery 10-channel battery sorters, the company achieved the following results in the sorting process of cylindrical lithium batteries:
Improve the sorting accuracy: The high-precision test system ensures the accuracy of the multi-parameter test results of each battery, reduces the phenomenon of missed detection and misjudgment, and improves the accuracy of battery classification.
Enhanced consistency: Standardized operating processes and high-precision equipment ensure that the battery performance is highly consistent in each channel, improving the consistency and stability of the battery.
Improve production efficiency: The automated all-in-one design significantly shortens the sorting time, improves production efficiency, and reduces labor costs.
Reduce the rate of defective products: standardized operation process and high-precision equipment reduce the error caused by human operation and reduce the rate of defective products.
Copyright © Zhengzhou CY Scientific Instrument Co., Ltd. All Rights Reserved Update cookies preferences
| Sitemap | Technical Support: